What does scaffold working height mean?
A listing for a “6 m scaffold” can refer to three different dimensions. Ask for the platform height and exact model first, then check each dimension against the work site.
| Dimension | What it measures | Altrex RS TOWER 52, TX520039 |
|---|---|---|
| Platform height | Distance from the base to the surface you stand on. | 4.20 m |
| Working height | The approximate height a person standing on the platform can reach, as stated by the manufacturer. | 6.20 m |
| Overall height | Distance from the base to the highest part of the assembled tower. | 5.44 m |
In this Altrex example, the working height is 2 m above the platform height. The Žalgirio pastoliai price list shows the same gap: its 6 m reach tower has a 4 m standing height. To paint the underside of eaves at 5.8 m, a tower with a 6.20 m working height leaves only 0.4 m to spare. Make sure you can handle your tools with a stable stance, without leaning out over the guardrails.
If you cannot reach the work, you need a taller configuration. The Altrex manual prohibits raising the platform with ladders, stepladders, boxes or any other object. Indoors, measure the clearance under beams, pipes and light fittings as well.
Mobile tower, frame scaffold or modular scaffold?
| Type | Where it fits | What to check on site |
|---|---|---|
| Mobile scaffold tower | Ceiling painting, light fitting maintenance or several separate work positions. | Level ground, clear routes and room for stabilisers at each position. |
| Frame façade scaffold | A continuous platform for work along a façade, such as rendering or insulation. | Wall length, ground levels, available tie positions and safe access to the working levels. |
| Modular scaffold | Corners, projections, irregular building shapes or changes in level. | Send photos and measurements so the supplier can assess a non-standard configuration. |
Which measurements should you send?
For a tower, measure the narrowest point on the way in and the clear area at the work position. Ask for the frame dimensions, usable deck dimensions and full footprint with supports. The TX520039 has a 1.35 m wide frame and a 1.85 m long deck. The assembly layout shows how much room the supports need. Indoor and outdoor platform height limits differ: in the RS TOWER 52 manual they are 12 m and 8 m. Check the manufacturer's configuration table for the stabilisers and ballast your height requires.
For a façade, measure each wall and mark balconies, corners, entrances and slopes. A scaffold face estimated at 12 m long by 6 m high gives a starting figure of 72 m² (12 × 6) for your enquiry. The supplier can confirm the chargeable area, number of bays and configuration for the selected system.
How much load must the platform carry?
Add up the people, tools and materials that will be on the deck at the same time. Façade scaffold loads are given as classes: in the PERI UP Easy instructions, load class 3 corresponds to a uniformly distributed load of 2.00 kN/m² (about 200 kg/m²) and class 4 to 3.00 kN/m². A tower manual may set the limit in kilograms and people instead: the RS TOWER 52 platform takes up to 250 kg and no more than 2 people. Check the limits for concentrated loads, the whole structure and levels loaded simultaneously.
If the working height must change at many points or the area is difficult to reach, discuss lifts and work platforms with a specialist. Their suitability depends on site access, the bearing capacity of the surface and the operating range of the specific machine.
How much does scaffold rental cost?
Mobile towers often have daily or weekly rates. Façade scaffold hire may be priced by the set or by square metre, with labour and transport charged separately. Compare offers for the same period using the total including VAT where applicable.
| Offer | Advertised equipment rental | What to confirm |
|---|---|---|
| Žalgirio pastoliai, 6 m reach, 0.80 m wide tower | €21.79 per day including VAT. | The rate for your full rental period and delivery. |
| Tvirtas sukibimas, 6 m working height, 1.4 m wide tower | €15 per day for 1–4 days, €80 per week or €230 per month, excluding VAT. | The transport cost. The supplier states that Sundays and public holidays are not charged. |
| FPN, façade set no. 1B (3 m long, 7.5 m working height, 19.5 m²) | €18 per week. | VAT, as the price list does not state it. €40 transport each way in Vilnius, €58 for assembly and dismantling, handling at €0.20/m² where needed. |
The Naudokis.lt listing for scaffolding in Pašilaičiai, Vilnius describes a wheeled scaffold with a working height of up to 3.8 m, a base rate of €10 per day and a €20 deposit held on your card. Rentals of 14 days or more get 20% off, and 28 days or more 25% off. You can collect it or have it delivered within 30 km at €0.50 per kilometre. Confirm the listed “200 × 80” measurement, platform height, model and included components with the owner.
How long should you rent scaffolding for?
Allow for handover, assembly, inspection, each stage of work, dismantling and return. Build in time for curing or drying where needed. Ask how weekends count and when the weekly rate applies.
| Job | How to allow enough time |
|---|---|
| Light fitting or gutter maintenance | One day may work if the job, inspections and return fit within the agreed handover times. |
| Painting a ceiling with two coats | Allow three days if you prepare and apply the first coat on day one, apply the second on day two and dismantle and return the tower on day three. |
| Façade repair and painting | If you schedule five days for the work, two for assembly and dismantling and two for weather delays, ask for a nine-day quote and check the minimum rental period. |
For temporary work, renting lets you select a configuration for the particular site and return it when the job is done. If the work repeats, include transport, inspections and storage in your rental versus purchase comparison.
Delivery, assembly and return
Checklist
- Agree delivery and collection times, both transport charges, the unloading point and who handles loading and unloading.
- For self-collection, check the longest component, total weight and vehicle payload. Secure the load for the journey.
- Ask for the components list and model instructions. Check whether the price includes the stabilisers, ties and access components required for the specified layout. Agree who will assemble, inspect and dismantle the scaffold.
- Check the deposit and how it is released, how to extend the rental, the return time and any charges for cleaning, late return or missing components.
In Vilnius, include the exact address, gate width and access restrictions in your enquiry. If the works need to fence off part of a street or pavement or restrict traffic, check the City of Vilnius permit procedure early.
What should you check before working at height?
Workplaces must prioritise collective fall protection for temporary work at height. Check guardrails, intermediate rails, toe boards, secured decks and the designated access route. Select any personal fall protection and anchor points through the risk assessment and site documentation. The Altrex manual states that a tower built to EN 1004-1 is not designed as an anchor point for it.
- Ground and stability. Check that the surface is firm, level and load-bearing, the castors are locked and the specified stabilisers or ties are in place. Move a tower only in the conditions set out in its manual, with people and materials off it. An RS TOWER 5 series tower must be reduced to a platform height of 6.2 m or less before it is moved.
- Inspections. On a construction site, scaffolding is inspected in the prescribed manner before first use, at regular intervals during use and after alteration, a break in use, bad weather or anything else that could affect its strength or stability. Check the deck, edge protection and access before climbing.
- Weather. Follow the wind limit in the manual. For RS TOWER 5 series towers it is 12.7 m/s (Beaufort 6), both in use and when moving. Allow for gusts and windy spots such as building corners. Stop work when wind, ice or slippery surfaces make it unsafe. The standard configurations of these towers are not calculated for tarpaulins or advertising boards. Have the responsible specialist approve any netting or sheeting before it goes on, as it changes the wind load.
Sources
Manufacturer specifications, workplace safety sources, the listing and public supplier prices were checked on 11 November 2026. The duration examples are planning scenarios. The cover image is illustrative.
- RS TOWER 52 mobile access tower — product specifications
- RS TOWER 51/51+/52/54/55 Safe-Quick® Guardrail — instruction manual (760284-D-1025)
- PERI UP Easy Facade Scaffold 67 and 100, Post Variant — Instructions for Assembly and Use, Standard Configuration
- CEN/TC 53 publications — EN 1004, EN 12810 and EN 12811
- Darbo įrenginių naudojimo bendrieji nuostatai, 2 priedo 4.1 ir 4.3 papunkčiai
- Darboviečių įrengimo statybvietėse nuostatai, 4 priedo IV skyriaus 37–38 punktai
- Directive 2009/104/EC on the use of work equipment, Annex II
- Leidimų kasinėti ir aptverti išdavimas
- Aliuminio bokštelių, fasadinių ir modulinių pastolių nuoma
- Aliuminio bokštelių nuoma ir kainos
- Pastolių nuoma Vilniuje, komplektas Nr. 1B